A practical field guide to the Texas rules that matter most when you are setting up and operating a seasonal retail fireworks stand.

This page focuses on retail stands where customers remain outside the structure. It is intentionally shorter and easier to use than the full state rulebook.

Important — Local Rules Can Be Stricter

State Rules Are the Baseline.

Counties, municipalities, fire marshals, and other local authorities may impose additional or more restrictive requirements. Always contact the county fire marshal or local authority having jurisdiction before building, placing, stocking, or opening a stand.

Harris County is a good example: its fire code adds requirements beyond the basic state stand rules, including fireworks control areas and approved flame-break construction.

Permit Required

One current retail permit for each retail stand / sales location.

18+ Supervisor

A supervisor age 18 or older must be on duty during all phases of operation.

Outward-Opening Doors

Under 16 ft: at least 1. 16 ft or longer: at least 2, one at each end.

6 FT Minimum Depth

At least 6 ft from the front of the customer counter to the back of the stand.

01Permits

Before You Open

Get the paperwork right before you stock the stand or begin selling.

Retail Permit

A retail fireworks permit is required for each stand or retail sales location. The original permit must be posted at the location and available for inspection.

Sales Tax Permit

A valid Texas sales tax permit is required as part of the retail permit process. Use the current Texas Department of Insurance online retail-fireworks permit process.

Buy From a Texas-Licensed Source

Retailers must purchase Fireworks 1.4G from a distributor or jobber licensed in Texas and sell only from legally permitted retail fireworks sites during authorized selling periods.

Keep Inventory Paperwork Available

Shipping information, invoices, and bills of lading related to the inventory at each retail stand must be available for inspection on request.

02Stand Setup

Build the Stand Right

These are the basic Texas construction, access, and customer-separation requirements for a retail fireworks stand.

Stand Construction

The stand must be constructed of wood, metal, masonry, concrete, or a combination of those materials. Sales from tents and motor vehicles are prohibited.

Walk Doors

Stands less than 16 feet long need at least one walk door that opens outward. Stands 16 feet or longer need at least two outward-opening walk doors, one at each end. Keep the path to walk doors unobstructed while operating.

Customer Counter & Interior Depth

Maintain at least 6 feet from the front of the customer counter to the back side of the stand. Do not display fireworks on the customer counter or allow customers to handle fireworks unless an attendant is directly assisting them.

Limit Combustible Decorations

Keep combustible interior decorations such as posters, signs, and decorations to a minimum.

Off-Highway Parking

Every retail fireworks site must provide customer parking off the highway.

Overnight Security

If the stand is used for overnight storage of Fireworks 1.4G, it must have suitable locking devices to prevent unauthorized entry.

03Fire & Safety

Keep Ignition Sources Away

The stand, the area around it, and the way employees work all matter during an inspection.

No Smoking

Smoking is not allowed in the retail fireworks site, and lighted cigars, cigarettes, or pipes are prohibited within 10 feet of the site. Post conspicuous “Fireworks” and “No Smoking” signs using letters at least 4 inches high.

No Open Flame

Do not illuminate or heat the stand with devices requiring an open flame or exposed heating element. Electric heaters must have a tip-over shutoff.

Exterior Fire Protection

If external fire danger exists around the sales area, provide equipment or facilities capable of extinguishing small exterior fires that could threaten the stand.

10-Foot Clear Zone

Keep at least 10 feet on all sides of the retail fireworks site free of high grass, empty cardboard boxes, and trash.

04Electrical

Wire It Like It Will Be Inspected

Electrical violations are easy to spot and are specifically called out on the state stand inspection form.

Service Height / Burial

Electrical service to the stand must be installed at least 8 feet above ground or buried underground according to standards acceptable to the local authority having jurisdiction.

Emergency Power Shutoff

Every stand using electricity needs a point of power interruption near a walk door that shuts off electrical supply to devices and equipment inside and on the stand.

Approved & Protected Wiring

Electrical wiring, equipment, and devices must be UL approved, securely mounted, and maintained to prevent electrical hazards. Wiring splices inside the stand must be enclosed in junction boxes.

No Extension Cords Inside

Drop cords with lights, extension cords, and bare wiring may not be used inside a retail fireworks stand.

Generator Setup

Keep the generator at least 10 feet from the stand in an area free of grass, trash, and other flammables. Store reserve fuel in an approved safety container and provide a portable fire extinguisher rated at least 6-B:C.

05Operations

Rules While You Are Open

A compliant stand can still fail an inspection if day-to-day operations get sloppy.

Adult Supervisor On Duty

A supervisor who is at least 18 years old must be on duty during all phases of operation. The permit holder and supervisor are responsible for compliance.

Sales Age Rules

Fireworks may not be sold or offered for sale to children under 16. State law also restricts employment of minors, including supervision requirements for 16- and 17-year-old sales personnel, with a limited immediate-family exception.

No Alcohol

Possession or consumption of alcoholic beverages is prohibited at the retail fireworks site. Sales personnel and supervisors may not be under the influence while on duty.

Keep Exits Clear

Maintain an unobstructed pathway to walk doors while the stand is operating. Doors needed for egress cannot be blocked or made inaccessible while occupied.

06Distances

Retail Stand Distance Quick Reference

These are the stand distances dealers are most likely to use in the field. Measure before you place the stand, generator, or signs.

100 FT

Flammable liquid / compressed gas dispensing

A retail fireworks stand may not sell within 100 feet of a place where flammable liquids or flammable compressed gases are stored and dispensed. Ex: Gas pumps, Propane tank exchange cages, Fuel filling ports.

10 FT

Clear area around the stand

Keep at least 10 feet on every side free of high grass, empty cardboard boxes, and trash.

10 FT

Generator separation

A generator must be at least 10 feet from the stand and located in an area free of grass, trash, and other flammable materials.

10 FT

Smoking boundary

Smoking is prohibited in the retail site, and lighted cigars, cigarettes, or pipes are prohibited within 10 feet of a site where fireworks are sold or stored.

8 FT

Overhead electrical service

Electrical service must be installed at least 8 feet above ground or buried underground to standards acceptable to the local AHJ.

6 FT

Customer counter to back of stand

Maintain at least 6 feet from the front of the customer counter to the back side of the stand.

Do Not Confuse This With Normal Stand Siting

Table 1 Is a Bulk-Storage Distance Table

Texas Rule §34.823 says the bulk-storage provisions apply to retail storage of more than 500 cases of Fireworks 1.4G. Those storage facilities must meet §34.824 Table 1 separation distances. The table uses net pyrotechnic / explosive composition and fuse weight, not gross case weight.

Net Weight of FireworksPassenger Railways / Public HighwaysInhabited Buildings
100 lb50 ft50 ft
200 lb50 ft60 ft
400 lb50 ft70 ft
600 lb50 ft80 ft
800 lb50 ft90 ft
1,000 lb50 ft100 ft
2,000 lb58 ft115 ft
3,000 lb62 ft124 ft
4,000 lb65 ft130 ft
5,000 lb68 ft135 ft
6,000 lb70 ft139 ft
8,000 lb73 ft140 ft
10,000 lb75 ft150 ft

07Local Rules

Your County May Require More

Texas rules are not the end of the checklist. Always verify the requirements for the exact county and jurisdiction where the stand will operate.

Harris County Example

Fireworks Control Areas & Flame Breaks

Harris County states that when its fire-code provisions conflict with the Texas Fireworks Rules, the more stringent provision applies. Its code limits a fireworks control area to no more than 125 pounds of pyrotechnic material and allows approved flame breaks every 8–10 feet to establish separate retail-stand control areas.

The Point

A stand that meets the state checklist may still need additional construction or spacing to satisfy the local fire marshal.

125 LB

Maximum pyrotechnic material per Harris County control area

8–10 FT

Approved flame-break spacing used to establish separate control areas

3/4"

Minimum plywood thickness for an approved flame break

FULL HEIGHT

Back wall to furthest shelf point, floor to underside of roof, with fire caulking

10 FT

From vehicles

20 FT

From other buildings

30 FT

From combustibles

50 FT

From cooking / open flame equipment

100 FT

From fuel or retail propane dispensers

Harris County also adds other stand-specific details, including smoke detectors, exit-travel requirements, minimum walk-door dimensions, and local permitting / inspection requirements. Do not build from this summary alone — confirm the current requirements with HCFMO for the specific site.

Verify Before Opening

Official References

This Dealer Academy page is an educational field guide, not a substitute for the complete Texas Occupations Code, Texas Administrative Code, an inspection, or instructions from your local authority having jurisdiction. Rules and local requirements can change.